About this manual

The manual applies to the KE and K7 Performance Level 'c' series produced by Gefran spa. It covers general information, mechanical dimensions, installation and positioning on the machine, the installation seat, wiring and calibration, NE21 and NE43 compatibility, sensor technical specifications, transport/storage/disposal, safety, and relay application notes.

Gefran melt pressure sensors with amplified electrical output are designed to measure pressure and temperature of melted plastic at different temperatures according to the filling fluid used. The manual also includes a safety manual for Performance Level 'c' sensors and installation guidance such as seat preparation, transducer installation, cleaning and calibration.

What's inside

  • General information
  • Mechanical dimensions
  • Installation and positioning on the machine
  • Installation seat
  • Wiring and calibration
  • NE21 and NE43 compatibility
  • Sensor technical specifications
  • Transport, storage and disposal
  • Safety
  • Safety Manual for Performance Level “c” sensors

Specifications

Correct temperature range538°C
Recommended installation torque50 Nm (maximum 56.5 Nm)
Dummy plug maximum pressure range2000 bar for all rods
Threading types1/2-20UNF-2B and M18x1.5

Frequently asked questions

What is the correct temperature range for the sensors?

The manual states the correct temperature range is 538°C.

What installation torque is recommended for the transducer?

The recommended torque is 50 Nm, and the maximum is 56.5 Nm.

Are the KE and K7 series compatible with NE21 and NE43?

Yes. The manual says the KE and K7 series are fully compatible with the NE21 and NE43 Namur recommendations.

How should a previously used installation hole be prepared?

It should be completely clean and free of any plastic residual before installation.