This is a KE PL‘c’ - K7 PL‘c’ INSTRUCTION MANUAL, which introduces the product's features and usage methods.
The manual applies to the KE and K7 Performance Level 'c' series produced by Gefran spa. It covers general information, mechanical dimensions, installation and positioning on the machine, the installation seat, wiring and calibration, NE21 and NE43 compatibility, sensor technical specifications, transport/storage/disposal, safety, and relay application notes.
Gefran melt pressure sensors with amplified electrical output are designed to measure pressure and temperature of melted plastic at different temperatures according to the filling fluid used. The manual also includes a safety manual for Performance Level 'c' sensors and installation guidance such as seat preparation, transducer installation, cleaning and calibration.
| Correct temperature range | 538°C |
|---|---|
| Recommended installation torque | 50 Nm (maximum 56.5 Nm) |
| Dummy plug maximum pressure range | 2000 bar for all rods |
| Threading types | 1/2-20UNF-2B and M18x1.5 |
The manual states the correct temperature range is 538°C.
The recommended torque is 50 Nm, and the maximum is 56.5 Nm.
Yes. The manual says the KE and K7 series are fully compatible with the NE21 and NE43 Namur recommendations.
It should be completely clean and free of any plastic residual before installation.