This manual is a user manual for WE PL 'c' - W7 PL 'c' products, which introduces the product overview, installation, use and maintenance.
This instruction manual applies to the Gefran WE PL 'c' and W7 PL 'c' Performance Level 'c' series of melt pressure sensors. It describes general information, mechanical dimensions, installation and positioning on the machine, installation seat preparation, wiring and calibration, and NE21/NE43 compatibility.
The document also includes sensor technical specifications, transport, storage and disposal instructions, a safety manual for Performance Level 'c' sensors, and relay application notes. It states that the sensors measure pressure and temperature of melted plastic and gives installation, cleaning, and removal procedures.
| Measured variables | Pressure and temperature of melted plastic |
|---|---|
| Correct temperature range | 315°C |
| WE series output | Current output |
| W7 series output | Voltage output |
| Recommended installation torque | 50 Nm; maximum 56.5 Nm |
| Dummy plug maximum pressure range | 2000 bar for all rods |
| Cleaning tool maximum torque | 15 Nm (1.5 Kgm) |
| Threading types | 1/2-20UNF and M18x1.5 |
The stated correct temperature range is 315°C.
The recommended torque is 50 Nm; the maximum is 56.5 Nm.
The WE series has current output, and the W7 series has voltage output.
Yes, the WE and W7 series are fully compatible with the NE21 and NE43 Namur recommendations.