This manual provides installation and operating instructions for the Fleck 5810 and 5812 SXT water softener or filter control valves.
This service manual provides detailed instructions for installing, operating, and maintaining Fleck 5810 and 5812 SXT control valves for water softeners or filters. It includes job specification sheets, operating parameters, installation steps, user programming, system disinfection, and troubleshooting. The manual also covers valve assemblies, accessories, wiring diagrams, and dimensional drawings. Safety warnings and compliance notes are included for proper installation and operation.
The document specifies electrical and plumbing requirements, including voltage, pressure, temperature, and material compatibility. It advises on proper installation techniques, such as air gap requirements, bypass valve use, and transformer connections. Maintenance and care instructions for the brine tank are also provided, along with diagnostic data viewing and master programming modes.
| Minimum Pressure | 20 psi / 1.4 bar / 138 kPa |
|---|---|
| Maximum Pressure | 125 psi / 8.61 bar / 861 kPa |
| Minimum Water Temperature | 34°F / 1°C |
| Maximum Water Temperature | 110°F / 43°C |
| Minimum Ambient Temperature | 34°F / 1°C |
| Maximum Ambient Temperature | 120°F / 52°C |
| Maximum Humidity | 75% |
| Input Voltage | 100-240 VAC |
| Input Frequency | 50/60 Hz |
| Output Voltage | 12 VDC |
| Output Current | 2.0 amps |
| Maximum Altitude | 2,000 meters |
Maximum pressure is 125 psi (8.61 bar / 861 kPa).
The controller requires 100-240 VAC input voltage.
The controller outputs 12 VDC at 2.0 amps.
Maximum ambient temperature is 120°F (52°C).