This manual is a maintenance manual for the Fleck 9000/9100/9500 home water conditioner, mainly introducing the composition, installation, use and maintenance methods of the product
This document is a service manual for the Fleck 9000, 9100, and 9500 series water conditioners. It provides detailed instructions on equipment configuration, installation, and start-up procedures, including specific requirements for water pressure, electrical facilities, and plumbing conditions. The manual outlines the setup of bypass valves and the correct assembly of the softener and drain lines.
| Minimum Water Pressure | 25 pounds (1.7 bar) |
|---|---|
| Maximum Water Pressure | 125 psi (8.6 bar) |
| Maximum Water Temperature | 110°F (43°C) |
| Electrical Supply | 115 volt, 60 Hertz |
| Minimum Drain Pipe Size | 1/2-inch |
| Recommended Lubricant | Non-aerosol silicone lubricant |
A minimum of 25 pounds (1.7 bar) of water pressure is required for the regeneration valve to operate effectively.
The unit requires a continuous 115 volt, 60 Hertz current supply that is always hot and cannot be turned off with another switch.