This manual introduces the functions and usage methods of products in FLECK 5800/5810/5812 XTRi (CONNECTED XTR2) SERVICE MANUAL pentair.com JOB SPECIFICATION SHEET, mainly including Job Number, Model Number, Water Hardness, Capacity Per Unit, Mineral Tank Size, Salt Setting per Regeneration, Regenerant Flow, Meter Size, System Type, Cycle Settings, Drain Line Flow Control, Brine Line Flow Control, Injector Size#, Battery Ins etc.


FLECK 5800/5810/5812 XTRi (CONNECTED XTR2) Service Manual - cover page
Brand
Fleck
Document type
Service Manual
Language
English
Pages
48
File format
PDF
File size
8.7 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
E7E05E72AE4C7FBBEC53D4A3A6CC2A4B

About this manual

This service manual provides detailed instructions for installing, operating, and troubleshooting the FLECK 5800/5810/5812 XTRi water softener controllers. It includes setup guidelines, electrical requirements, plumbing specifications, and safety precautions. The document also covers controller programming, regeneration cycles, and diagnostic procedures for field technicians. Technical specifications such as pressure, temperature, and voltage limits are provided for proper system operation.

What's inside

  • Operating Parameters
  • Job Specification Sheet
  • Installation
  • Start-Up Instructions/Flushing & Conditioning
  • System Disinfection
  • Touchscreen Control Features
  • Master Settings Programming
  • Regeneration
  • Control Operation
  • Master Reset

Specifications

Minimum Pressure20 psi (1.4 bar/138 kPa)
Maximum Pressure125 psi (8.61 bar/861 kPa)
Minimum Water Temperature32°F (0°C)
Maximum Water Temperature110°F (43°C)
Minimum Ambient Temperature32°F (0°C)
Maximum Ambient Temperature120°F (62°C)
Maximum Humidity1%
Input Voltage100-240 VAC
Input Frequency50/60 Hz
Output Voltage12 VDC
Output Current2.0 amps
Maximum Altitude2,000 meters

Frequently asked questions

What is the maximum water pressure this unit can handle?

Maximum pressure is 125 psi (8.61 bar/861 kPa).

What is the minimum water temperature for operation?

Minimum water temperature is 32°F (0°C).

What is the maximum ambient temperature for installation?

Maximum ambient temperature is 120°F (62°C).