This manual describes the components and installation, operation, and maintenance methods of the Fleck 2900s series water treatment equipment.
This document is a service manual for the Fleck 2900s series of water treatment equipment. It provides detailed instructions for the installation, start-up, and operation of the control valves and associated systems. The manual covers various timer models, including the 3200, 3210, 3220, and 3230, detailing setting procedures for regeneration schedules and manual regeneration.
The guide also addresses the assembly and servicing of specific components such as the control valve with injector, environmental and manual powerheads, and various brine system assemblies (1600, 1650, 1700, 1710 series). It includes troubleshooting tips, flow diagrams, and wiring information for different system configurations.
| Minimum Water Pressure | 20 pounds (1.4 bar) |
|---|---|
| Maximum Water Pressure | 125 psi (8.6 bar) |
| Maximum Water Temperature | 110°F (43°C) |
| Residential Drain Line Size | 1/2" (13 mm) |
| Backwash Flow Rate Limit | 7 gpm (26.5 Lpm) |
Granulated or rock salt should not be used; standard salt is required.
The black center knob will make one revolution in approximately three hours.