FLECK 5812 SXT Manuals

ManualLib has 2 documents for the FLECK 5812 SXT: 2 service manuals. Every file can be read online or downloaded as a PDF for free.

Service Manual 2

Key facts

Brand
Fleck
Model
5812 SXT
Industry
Appliances
Documents
2
Languages
EN
Last added
2023-10-18

Start here

FLECK 5810 & 5812 SXT Water Softener or Filter Control Valve Service Manual

FLECK 5810 & 5812 SXT Water Softener or Filter Control Valve Service Manual

Service Manual 32 pages · 9.2 MB · EN

This service manual provides detailed instructions for installing, programming, and maintaining the FLECK 5810 & 5812 SXT control valves used in water softening or filtration systems. It includes operating parameters, safety warnings, installation steps, troubleshooting, and wiring diagrams. The manual also covers user programming, system disinfection, and care of the brine tank. It is intended for technicians servicing the valve, not for general users installing the system.

The valves are designed for upflow/downflow applications and require a minimum of 20 psi water pressure and 120 VAC electrical supply. Installation must comply with local plumbing and electrical codes, and the unit must be installed in a temperature range of 34°F to 120°F. The manual includes dimensional drawings, flow diagrams, and diagnostic data viewing instructions.

Read online

FLECK 5812 SXT specifications

Minimum Water Pressure20 psi (1.4 bar/138 kPa)
Maximum Water Pressure125 psi (8.61 bar/861 kPa)
Minimum Water Temperature34°F (1°C)
Maximum Water Temperature110°F (43°C)
Minimum Ambient Temperature34°F (1°C)
Maximum Ambient Temperature120°F (52°C)
Maximum Humidity75%
Input Voltage100-240 VAC
Input Frequency50/60 Hz
Output Voltage12 VDC
Output Current2.0 amps
Maximum Altitude2,000 meters

Source: FLECK 5810 & 5812 SXT Water Softener or Filter Control Valve Service Manual

All FLECK 5812 SXT documents by type

Questions answered in these manuals

What is the minimum water pressure required for the valve to operate?

A minimum of 20 psi (1.4 bar) of water pressure is required for the regeneration valve to operate effectively.

From: FLECK 5810 & 5812 SXT Water Softener or Filter Control Valve Service Manual

What is the maximum water temperature the valve can handle?

The maximum water temperature is 110°F (43°C).

From: FLECK 5810 & 5812 SXT Water Softener or Filter Control Valve Service Manual

What is the maximum water pressure this valve can handle?

Maximum pressure is 125 psi (8.61 bar / 861 kPa).

From: Fleck 5810 and 5812 SXT Water Softener or Filter Control Valve Service Manual

What is the input voltage requirement for the controller?

The controller requires 100-240 VAC input voltage.

From: Fleck 5810 and 5812 SXT Water Softener or Filter Control Valve Service Manual