This document is about the instruction manual of Fleck 2510 Greensand filter, which introduces the components, installation, use and maintenance of the filter
This document serves as an installation and start-up guide for the Fleck 2510 Greensand filter system. It includes a detailed packing list for different model sizes (1.0, 1.5, 2.0, and 2.5 cubic foot) and outlines pre-installation steps, such as selecting a suitable location and ensuring proper water pressure between 20 and 90 PSI. The guide also covers best practices for piping and drain installation, emphasizing the correct connection of inlet and outlet pipes and the use of ball valves and hose bibs.
| Minimum Pressure | 20 PSI |
|---|---|
| Maximum Pressure | 90 PSI |
| Installation Time | 3 to 5 hours |
| First Backwash Duration | 90 minutes |
| Regeneration Duration | about 90 minutes |
| Regeneration Frequency | every 3 to 7 days |
The filter is typically set to regenerate every 3 to 7 days, preferably during the middle of the night.
The first backwash and rinse cycle takes approximately 90 minutes to complete.
No, Teflon tape should not be used on the tank itself or the threads where the control valve attaches to the tank.