This document is the maintenance manual of Fleck 5600SXT Co-Flow water conditioner, which mainly introduces the function characteristics, installation, startup, timer function, fault troubleshooting and other contents of the equipment.
This service manual provides step-by-step instructions for installing and maintaining the Fleck 5600SXT co-flow water conditioner. It covers plumbing requirements, electrical setup, valve programming, and troubleshooting. The manual includes detailed diagrams for wiring and flow, as well as specifications for timer settings and flow controllers. It also explains how to perform manual regeneration cycles and adjust system parameters for optimal performance.
The unit is designed for residential or commercial use and requires a minimum water pressure of 1.4 bar. It includes features such as backup power for clock retention, programmable regeneration cycles, and error indicators. The manual is written in French and includes technical specifications for flow rates, tank sizes, and controller settings.
| Minimum Water Pressure | 1.4 bar (20 lb) |
|---|---|
| Maximum Water Pressure | 8.6 bar (125 psi) |
| Maximum Water Temperature | 43 °C (110 °F) |
| Backup Power Duration | 48 hours minimum |
| Flow Controller Outlet Size | Minimum 13 mm (1/2 po) |
| Flow Controller Outlet Size for High Flow | 19 mm (3/4 po) |
A minimum water pressure of 1.4 bar (20 lb) is required for proper valve regeneration operation.
The backup power lasts a minimum of 48 hours to retain the clock and calendar.
The maximum water temperature is 43 °C (110 °F).
Turn the manual regeneration knob slowly clockwise until the micro-switch on the program lever lifts off the first set of pins. Allow the drive motor to move the piston to the first regeneration step and stop. At each position change of the program switch, the valve moves to the next regeneration step. Always let the motor stop before moving to the next set of pins or spaces.