Linear Technology LT3752/LT8311 Active Clamp Forward Converter Demonstration Manual

This is an LT3752/LT8311 active clamp forward converter with synchronous rectification function, suitable for automotive, industrial and military applications. It operates at 200kHz frequency and produces a regulated 12V at 13A output from a wide input voltage range of 9V to 36V, achieving an efficiency exceeding 93%. The DC2175 circuit features soft-start which prevents output voltage overshoot on startup or when recovering from overload condition. The DC2175 also has a precise overcurrent protection circuit that allows for continuous operation under short circuit conditions. The low power dissipation under a short circuit ensures high reliability even during prolonged short circuit conditions. The LT3752 includes an internal constant frequency flyback controller for creating a housekeeping voltage supply. The housekeeping supply is able to efficiently provide bias for both primary and secondary ICs, and eliminates the need to generate bias supplies from auxiliary windings in the main forward transformer. The housekeeping supply also allows bias to any secondary side IC before the main forward converter starts switching. Please refer to the LT3752 data sheet for design information.


Linear Technology LT3752/LT8311 Active Clamp Forward Converter Demonstration Manual - cover page
Brand
Linear Technology
Category
DC/DC Converter
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
306 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
531C8990E76B063BAE92FF8C5B05E6C2

About this manual

This document provides setup instructions and specifications for the LT3752/LT8311 active clamp forward converter demonstration circuit. It operates at 200kHz and delivers a regulated 12V at 13A from a 9V to 36V input, with efficiency exceeding 93%. The circuit includes soft-start and overcurrent protection for reliable operation.

The manual includes a parts list, schematic diagram, and quick start procedure for testing and measuring performance parameters such as output ripple, transient response, and efficiency.

What's inside

  • Quick Start Procedure
  • Parts List
  • Schematic Diagram
  • Specifications
  • Thermal Maps
  • Output Ripple Measurement
  • Transient Response Waveform

Specifications

Input Supply Range9V to 36V
Output Voltage12V
Maximum Output Current13A
Switching Frequency200kHz
Output Ripple100mVP–P
Efficiency93%

Frequently asked questions

What is the operating input voltage range?

The input voltage range is 9V to 36V.

What is the output voltage and current?

The output is regulated at 12V with a maximum current of 13A.

What is the switching frequency?

The switching frequency is 200kHz.

What is the efficiency of the converter?

The efficiency exceeds 93% at 24V input and 13A output.