This document is the user manual of Fluke Ti9, Ti10, Ti25, TiRx, TiR and TiR1 thermal imagers.
This manual covers the operation and features of Fluke’s handheld thermal imagers, including models Ti9, Ti10, Ti25, TiRx, TiR and TiR1. It explains how to charge the battery, navigate menus, adjust settings like temperature range and display palettes, and save or transfer images. Safety precautions and warranty information are also included.
The devices display thermal and visual images on a 640x480 screen, with varying temperature ranges depending on model. Some models support IR-Fusion® and voice annotation. Images can be saved to an SD card and analyzed using SmartView® software.
| Display Resolution | 640 X 480 |
|---|---|
| Temperature Range | Ti9 and Ti10: +250°C; Ti25: +350°C; TiRx, TiR, TiR1: +100°C |
| Battery Type | Rechargeable Nickel Metal-Hydride |
| Image Transfer | Via SD Memory Card and included card reader |
| Software | SmartView® for image analysis and report generation |
Ti9 and Ti10: up to +250°C; Ti25: up to +350°C; TiRx, TiR, TiR1: up to +100°C.
Yes, remove the SD memory card and connect it to a PC using the included card reader.
SmartView® software is included for image analysis and report generation.