This document is the technical and service manual of KHS1872 + CH1872 KHS2472 + CH2472 DC INVERTER SPLIT SYSTEM AIR CONDITIONER from Hisense
This service manual provides detailed instructions for installing, servicing, and troubleshooting Sanyo DC inverter split system air conditioners. It includes specifications, refrigerant handling procedures for R410A, electrical wiring diagrams, and troubleshooting guides for fan motors, noise, and electromagnetic interference. Safety precautions are emphasized, especially for electrical work and refrigerant handling.
The manual covers both indoor and outdoor unit specifications, operating ranges, performance data, and maintenance procedures. It also includes detailed diagrams and tables for refrigerant flow, electrical characteristics, and dimensional data for the units.
| Voltage Rating | 230V Single-Phase 60Hz |
|---|---|
| Cooling Total Capacity | 17,500 BTU (4,000 to 17,500) |
| Refrigerant | R410A / 2.87 lbs (1,300 g) |
| Compressor Type | DC Twin Rotary (Inverter) |
| Indoor Unit Dimensions | 298 x 1,065 x 218 mm |
| Indoor Unit Weight | 26.5 lbs (12.0 kg) |
The unit uses R410A refrigerant, with a charge of 2.87 lbs (1,300 g) at shipment.
The voltage rating is 230V Single-Phase 60Hz.
The cooling capacity is 17,500 BTU (4,000 to 17,500).
Cooling: Indoor 67°F D.B. to 95°F D.B., Outdoor 0°F D.B. to 115°F D.B. Heating: Indoor 0°F D.B. to 80°F D.B., Outdoor 0°F D.B. to 75°F D.B.