Fisher™ 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter Installation Manual

Describes the features and uses of Fisher™ 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter, as well as installation methods.


Fisher™ 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter Installation Manual - cover page
Brand
Fisher
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
60
File format
PDF
File size
1.1 MB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
1E3AD5CBA91101ED9B7A29C0D1E70E07

About this manual

This instruction manual provides comprehensive guidance for the installation, operation, calibration, maintenance, and parts ordering of Fisher 3610J, 3620J, 3610JP, 3620JP, 3611JP, and 3621JP positioners. It also includes field installation information for the Fisher 3622 electro-pneumatic converter. The document details mounting procedures for various actuator styles, including diaphragm rotary, piston rotary, and sliding-stem actuators.

What's inside

  • Introduction
  • Specifications
  • Mounting
  • Pressure Connections
  • Electrical Connections
  • Calibration
  • Maintenance
  • Parts Ordering
  • Hazardous Area Classifications
  • Diagnostic Connections

Specifications

Input Signal3 to 15 psig or 6 to 30 psig (3610J/JP/11JP)
Input Signal4 to 20 mA DC (3620J/JP/21JP)
Operating Temperature-40 to 82°C (-40 to 180°F)
Rotary Valve Rotation60, 75, or 90 degrees
Sliding-Stem Valve Travel102 mm (4 inches)
Weight (3610J)2.5 kg (5.6 pounds)
Weight (3620J)3.6 kg (8.0 pounds)

Frequently asked questions

What is the minimum recommended supply pressure?

The minimum recommended supply pressure is 0.3 bar (5 psig) above the actuator requirement.

Is the 3620J positioner approved for use with natural gas?

No, the 3620J, 3620JP, and 3621JP positioners are not approved for use with natural gas as the supply medium.

What is the maximum supply air demand for the 3610J?

The maximum supply air demand for the 3610J is 1.4 bar (20 Psig) with a supply of 13 normal m3/hour (490 scfh).