Describes the features and uses of Fisher™ 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter, as well as installation methods.
This instruction manual provides comprehensive guidance for the installation, operation, calibration, maintenance, and parts ordering of Fisher 3610J, 3620J, 3610JP, 3620JP, 3611JP, and 3621JP positioners. It also includes field installation information for the Fisher 3622 electro-pneumatic converter. The document details mounting procedures for various actuator styles, including diaphragm rotary, piston rotary, and sliding-stem actuators.
| Input Signal | 3 to 15 psig or 6 to 30 psig (3610J/JP/11JP) |
|---|---|
| Input Signal | 4 to 20 mA DC (3620J/JP/21JP) |
| Operating Temperature | -40 to 82°C (-40 to 180°F) |
| Rotary Valve Rotation | 60, 75, or 90 degrees |
| Sliding-Stem Valve Travel | 102 mm (4 inches) |
| Weight (3610J) | 2.5 kg (5.6 pounds) |
| Weight (3620J) | 3.6 kg (8.0 pounds) |
The minimum recommended supply pressure is 0.3 bar (5 psig) above the actuator requirement.
No, the 3620J, 3620JP, and 3621JP positioners are not approved for use with natural gas as the supply medium.
The maximum supply air demand for the 3610J is 1.4 bar (20 Psig) with a supply of 13 normal m3/hour (490 scfh).