Provides installation, operation, maintenance, and parts ordering information for NPS 1 through 8 Fisher V500 eccentric plug rotary control valves.
The Fisher V500 is a flanged or flangeless rotary control valve featuring a self-centering seat and an eccentrically rotating plug. It is designed for throttling or on-off service and is compatible with various actuators, including diaphragm and piston types. The valve supports both forward and reverse flow directions and mates with CL150, CL300, or CL600 raised face pipeline flanges, as well as DIN PN10 through PN100 flanges.
The document provides detailed instructions for installation, including actuator mounting and travel adjustment. It also outlines maintenance procedures such as packing maintenance, replacing seals and bearings, and adjusting the valve for specific flow directions or actuator mounting styles. Technical specifications, shaft dimensions, and parts ordering information are included.
| Valve Sizes | NPS 1, 1-1/2, 2, 3, 4, 6, and 8 |
|---|---|
| Shutoff Classification | Class IV per ANSI/FCI 70-2 |
| Flow Characteristic | Modified linear |
| Valve Plug Rotation | Counterclockwise to close |
The valve has a Class IV shutoff classification per ANSI/FCI 70-2 and IEC 60534-4.
Reverse flow is recommended for erosive and general service.
Yes, it is recommended to install the valve shaft in a horizontal direction for best shutoff performance.