This is the user manual for Morningstar company TriStar MPPT Solar Charge Controller TS-MPPT-30, TS-MPPT-45 & TS-MPPT-60 models.
This document serves as a Quick Start Guide for the Morningstar TriStar MPPT Solar Charge Controller models TS-MPPT-30, TS-MPPT-45, and TS-MPPT-60. It outlines the contents of the box, required tools, and critical safety warnings regarding hazardous voltage and the need for a Ground Fault Disconnect (GFDI) device. The guide specifies that the unit must be installed by a qualified technician in accordance with local electrical regulations.
| Battery Voltage | 12 Vdc, 24 Vdc, or 48 Vdc |
|---|---|
| Maximum PV Open Circuit Voltage | 150 Vdc |
| Maximum Battery Current (TS-MPPT-30) | 30 A |
| Maximum Battery Current (TS-MPPT-45) | 60 A |
| Maximum Battery Current (TS-MPPT-60) | 60 A |
| Battery Operating Voltage Range | 8 to 72 V |
| Nominal Maximum Output Power (TS-MPPT-30) | 400 Watts |
| Nominal Maximum Output Power (TS-MPPT-45) | 800 Watts |
| Nominal Maximum Output Power (TS-MPPT-60) | 800 Watts |
| Battery Types Supported | Flooded, Sealed, AGM, Lithium |
Required tools include a #2 Philips Screwdriver, 3/16 (5 mm) & 1/8" (3.8 mm) Flathead Screwdriver, a Drill with a 1/8" (3.8 mm) bit, and a Multimeter.
No, the TriStar charge controller must be installed by a qualified technician in accordance with the electrical regulations of the country of installation.
No, the unit is not provided with a GFDI device and must be used with an external GFDI device as required by Article 690 of the National Electrical Code.
The power up sequence requires connecting the Battery/Battery Bank first, followed by connecting the Solar array.