This manual contains detailed installation and operation instructions for the SB3024iL and SB3024DiL solar charge controllers, including product features, safety precautions, operation steps, etc.
This manual covers the installation and operation of the Blue Sky Energy Solar Boost 3024iL and SB3024DiL Maximum Power Point Tracking (MPPT) photovoltaic battery charge controllers. These units are designed to charge 12V or 24V flooded or sealed lead-acid batteries with capacities ranging from 20 to 10,000 amp-hours. The SB3024DiL model includes an optional digital display for monitoring battery voltage and output charge current.
| Maximum Current Rating | 30A or 40A depending on PV modules and battery voltage |
|---|---|
| Battery Voltage Range | 12V (6-cell) or 24V (12-cell) |
| Battery Capacity Range | 20 to 10,000 amp-hours |
| Auxiliary Output Functions | 2 A auxiliary battery charger or 20A load controller |
| Battery Operating Voltage | Minimum 9V |
The unit requires a battery connected with a minimum voltage of 9V to operate.
No, the unit must never be installed in a battery compartment or in the presence of explosive gases.
The unit must be connected to a circuit provided with 50A maximum branch-circuit over current protection.