Blue Sky Energy SB2512i-HV / SB2512iX-HV MPPT Solar Charge Controller Installation and Operation Manual

This manual introduces the features and characteristics of the Blue Sky Energy Solar Boost 2512i-HV / SB2512iX-HV MPPT solar charge controller, including maximum power point tracking, 20/25 amps 12VDC, installation and operation instructions.


Blue Sky Energy SB2512i-HV / SB2512iX-HV MPPT Solar Charge Controller Installation and Operation Manual - cover page
Brand
Blue Sky Energy
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
774 KB
Published
13 October, 2023
Updated
13 October, 2023
MD5 checksum
931C104B166A23D1C4B792FD64B2D55B

About this manual

This manual covers the installation and operation of the Blue Sky Energy Solar Boost 2512i-HV and 2512iX-HV, which are 25 amp Maximum Power Point Tracking (MPPT) photovoltaic charge controllers. The SB2512iX-HV is the full-featured version, while the SB2512i-HV omits certain features such as battery temperature sensing and auxiliary output to reduce cost. Both models utilize patented MPPT technology to increase charge current and allow the use of higher voltage 60-cell modules.

What's inside

  • Important Safety Instructions
  • Product Description
  • Features Omitted in the Solar Boost 2512i-HV
  • Operation
  • Charge Status Indicator
  • Installation
  • Mounting
  • Troubleshooting Guide
  • Specifications
  • Five Year Limited Warranty

Specifications

Maximum Charge Current25A
Battery Voltage12VDC
Maximum Battery Capacity2,000 amp-hours
Charge Voltage Setpoint Range13.2V to 15.0V
Charge Status Indicator ModesOFF, BULK, ABSORPTION, FLOAT, EQUALIZE

Frequently asked questions

What is the difference between the SB2512i-HV and SB2512iX-HV?

The SB2512iX-HV includes a battery temperature sensor input, equalization capability, full IPN Network interface, and an auxiliary output, while the SB2512i-HV omits these features.

What is the maximum short circuit current for the PV array?

The unit must not be connected to a PV array capable of producing greater than 20 amperes of short circuit current at STC.

What is the required torque for battery and PV wiring terminals?

Battery, PV and Auxiliary Output terminals must be tightened to 9 in-lb (1 Nm).

Download PDF (774 KB)

More Blue Sky Energy Manuals


View all Blue Sky Energy manuals →