This is the user manual of Blue Sky Energy solar charge controller SB2512i-HV and SB2512iX-HV. The charger controller has 20/25A current and 12V voltage, maximum power of 20/25A.
This manual covers the installation, wiring, and operation of the Solar Boost™ 2512i(X)-HV series Maximum Power Point Tracking (MPPT) photovoltaic battery charge controllers. These units are designed to charge 12V lead-acid batteries using a sophisticated 3-stage or 2-stage charge control system.
| Maximum Charge Current | 25 AMP |
|---|---|
| Battery Voltage | 12VDC |
| Maximum Battery Capacity | 2,000 amp-hours |
| Charge Control Stages | 3-Stage (Bulk, Absorption, Float) |
| MPPT Efficiency Gain | up to 30% |
The SB2512i-HV omits battery temperature sensor input, equalization capability, full IPN Network interface, and auxiliary output.
A battery must be connected with a minimum voltage of 9V for the unit to operate.
Do not connect to a PV array capable of producing greater than 20 amperes of short circuit current.