About this manual

This manual covers the installation, wiring, and operation of the Solar Boost™ 2512i(X)-HV series Maximum Power Point Tracking (MPPT) photovoltaic battery charge controllers. These units are designed to charge 12V lead-acid batteries using a sophisticated 3-stage or 2-stage charge control system.

What's inside

  • Important Safety Instructions
  • Product Description
  • Features Omitted in the Solar Boost 2512i-HV
  • Operation
  • Charge Status Indicator
  • Installation
  • Mounting
  • Troubleshooting Guide

Specifications

Maximum Charge Current25 AMP
Battery Voltage12VDC
Maximum Battery Capacity2,000 amp-hours
Charge Control Stages3-Stage (Bulk, Absorption, Float)
MPPT Efficiency Gainup to 30%

Frequently asked questions

What features are omitted in the SB2512i-HV model?

The SB2512i-HV omits battery temperature sensor input, equalization capability, full IPN Network interface, and auxiliary output.

What is the minimum battery voltage required for operation?

A battery must be connected with a minimum voltage of 9V for the unit to operate.

What is the maximum short circuit current allowed?

Do not connect to a PV array capable of producing greater than 20 amperes of short circuit current.