This manual describes how to connect the GP to Fuji Electric PLCs.
This document provides instructions for connecting the GP-PRO/PBIII for Windows software to Fuji Electric Corporation PLCs. It covers system structures and cable diagrams for different PLC series, including MICREX-F (using Link I/F, T-Link, FLT-ASFK, and FLEX-PC) and FLEX-PC (using Link I/F and CPU Direct Connection).
The manual details specific cable diagrams for RS-232C and RS-422 interfaces, including recommended cables from Digital and third-party manufacturers like Hitachi Densen and Hirose. It also lists supported device addresses and communication setup parameters such as baud rate, data length, stop bits, parity, and flow control for each interface type.
| Baud Rate | 19200 bps |
|---|---|
| Data Length | 7 bits or 8 bits |
| Stop Bit | 1 bit or 2 bits |
| Parity Bit | Even, Odd, or None |
| Data Flow Control | ER Control |
For the RS-232C connection, use a cable length less than 15m.
When making your own cable connections, we recommend using Hitachi Densen's CO-SPEV-SB(A)3P*0.5S cable.