The M910138 electronic controller is a microprocessor controlled thermostatic device, designed to control cooling , heating and defrost for the refrigeration. It actuates in a temperature range from -40°F to +139°F. A single setpoint is used for heat and cooling, the system will automatically switch modes to maintain the setpoint entered.


ATC M910138 ATC Cooling Controller User Manual - cover page
Brand
ATC
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
495 KB
Published
12 October, 2023
Updated
12 October, 2023
MD5 checksum
DD8909989C5009DA7E3C2C418F9679B2

About this manual

The ATC M910138 is a microprocessor-controlled thermostatic device designed to manage cooling, heating, and defrost cycles in refrigeration applications. It features a control panel with an LED display, allowing users to set a single point for automatic mode switching between heat and cool based on temperature differentials.

The document details system parameters such as evaporator coil temperature monitoring, various defrost modes (automatic by time or temperature, and manual), and drip modes. It also explains how to access the parameter menu using a password, adjust settings like cooling/heating differentials, and utilize test modes for troubleshooting outputs.

What's inside

  • System Operation
  • Numerical Display
  • Setpoint Control
  • Cooling Mode
  • Heating Mode
  • Defrost Functions
  • Drip Mode
  • System Parameters
  • Failures and Alarms
  • Test Mode

Specifications

Operating Temperature Range (Controller)-40°F to +139°F
Nominal Voltage Range12 to 24VDC
Functional Voltage Range10 to 29VDC
Peak Voltage Tolerance32VDC for 5 minutes
Polarity Reversion Support-12Vdc / -24Vpc indefinitely
Maximum Output Current per Pin400mA

Frequently asked questions

How do I turn on the device?

Press the power button once quickly to turn on the device.

What is the password for accessing system parameters?

The password required to access the parameter menu is 041.

How do I enter Test Mode?

Press simultaneously the up and down arrows for 3 seconds, type the password 023, then press Enter.

Can I block changes to the setpoint temperature?

Yes, changing parameter 'bL' to 1 will block setpoint changes.