Woodward DSS-2 Two-Channel Digital Speed Switch User Manual

The DSS-2 Two-Channel Digital Speed Switch Manual provides instructions for installation, operation, and servicing of the equipment. It emphasizes the need for an overspeed shutdown device to protect the prime mover and the potential risks of not having one. The manual also suggests the installation of overtemperature or overpressure shutdown devices for safety. A caution is provided regarding turning off the charging device before disconnecting the battery to prevent damage to the control system. The manual highlights the importance of addressing surge energy in systems with large inductive loads and recommends the installation of suppression devices. It also warns about the sensitivity of electronic controls to static and provides precautions to prevent damage.


Woodward DSS-2 Two-Channel Digital Speed Switch User Manual - cover page
Brand
Woodward
Document type
User Manual
Language
English
Pages
66
File format
PDF
File size
3.7 MB
Published
01 March, 2023
Updated
27 September, 2023
MD5 checksum
2A47890C1E6B0424A8D61596C37C5641

About this manual

The DSS-2 is a two-channel electronic speed switch designed for engine applications to perform functions such as starter motor disable and overspeed protection. It monitors engine RPM via a magnetic pickup input and controls two independent relays based on user-selected setpoints.

As shipped, the unit allows manual adjustment of speed setpoints using multi-turn potentiometers. For advanced features like autocrank control or glow plug preheat, users can attach the All-purpose Calibration Tool (ACT) to configure additional parameters such as frequency range and relay logic modes.

What's inside

  • General Information
  • Specifications
  • Installation
  • Calibration
  • ACT Operation
  • Troubleshooting

Frequently asked questions

What is the DSS-2 and what is it designed for?

The DSS-2 is a two-channel electronic speed switch designed for use on engine applications to perform functions like starter motor disable and engine overspeed protection.

What is the frequency range for manual adjustment on most applications?

As shipped from the factory, the DSS-2 can be manually adjusted on applications that supply a MPU frequency of 2500 to 5000 Hz.

What is the maximum length allowed for power cabling?

Power cabling is limited to less than 10m (32.8') in total length.

Download PDF (3.7 MB)

More Woodward Manuals


View all Woodward manuals →