This manual covers the operation, configuration, and specifications of the Woodward CPC-II hydraulic pressure-regulating converter for steam turbine valves.
The Woodward CPC-II is an electrohydraulic valve controller designed to regulate single-acting steam turbine valves. It ensures stable steam flow and improved load control by precisely positioning the valve based on electrical input signals. The unit features a robust design with redundancy options, self-cleaning capabilities for silt removal, and precise pressure regulation suitable for hazardous environments.
| Performance Accuracy | < ±0.2 % of full range |
|---|---|
| Repeatability | 0.1 % of full range |
| Temperature Drift | < ±0.01 % of full range /°C |
| Pressure stability | < ±2 % of setpoint |
| Operating Temperature Range | (–40 to +85) °C |
| Electrical Input Supply | (18 to 32) V (dc) |
It includes a special configurable 'Silt Buster' routine to routinely remove internal silt build-up in the slave unit.
The recommended filtration is (24 to 40) μm nominal.