Fisher POSI-SEAL A31A High-Performance Butterfly Valve Installation and Maintenance Guide

This document is a guide manual for the A31A high-performance butterfly valve. The manual includes installation, maintenance, and spare parts ordering information for this product. The valve can be provided with a wafer or lug-style valve body and various sealing components. It has tight shut-off performance and can withstand a range of pressures. The valve shaft can be combined with various types of actuators, and the maximum inlet pressure/temperature rating complies with regulations.


Fisher POSI-SEAL A31A High-Performance Butterfly Valve Installation and Maintenance Guide - cover page
Brand
Fisher
Document type
Service Manual
Language
Chinese
Pages
24
File format
PDF
File size
1.3 MB
Published
10 January, 2023
Updated
28 September, 2023
MD5 checksum
D9017E2B30C1E25416897B58C6495F09

About this manual

This manual provides instructions for the installation, operation, and repair of Fisher POSI-SEAL® A31A high-performance butterfly valves in sizes from 14 to 24 inches. It details specifications regarding valve body types, end connections, pressure ratings, and material temperature limits.

The document outlines procedures for installing the actuator, adjusting travel limits, and performing maintenance tasks such as packing adjustment, shaft electrical connection, and disassembly of the actuator and valve components. It also includes information on ordering spare parts. This manual is written in Chinese.

What's inside

  • 前言
  • 产品说明
  • 技术规格表
  • 安装
  • 阀门定位
  • 阀门安装前
  • 调整执行机构行程限位或行程
  • 填料的调整与阀轴的电气连接
  • 维修
  • 备件定购

Specifications

Valve Sizes14 to 24 inches
End ConnectionsWafer (flangeless) or Single Flange (lugged)
Pressure ClassesANSI 150 and 300 lb
Shut-off Class (Soft Seal)Class VI (Bubble-tight)
Flow CharacteristicEqual Percentage

Frequently asked questions

What are the recommended installation orientations for the valve?

The valve can be installed in any direction, but it is recommended that the drive shaft be horizontal and the actuator vertical.

How should the valve be oriented regarding flow direction?

The high-pressure shut-off side of the valve should face the direction indicated by the flow arrow.

What safety precautions are required before maintenance?

Pressure must be cut off from the control valve and line, released from both sides of the body, and all pressure lines to the actuator must be disconnected.