This document is the user manual for the Soil Tension Transmitter (485 model) with version 2.0. The manual provides an overview of the product, its features, main parameters, and system framework. The product is designed for monitoring soil moisture levels in agricultural crops to determine if irrigation is needed. It offers fast response, accurate measurements, and is not affected by agricultural activities. The product uses the standard Modbus-RTU485 communication mode and can communicate up to 2000 meters.


Soil Tension Transmitter User Manual (485 Model) - cover page
Brand
PR
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
14
File format
PDF
File size
628 KB
Published
02 October, 2022
Updated
28 September, 2023
MD5 checksum
C519E0379AC659322BC415915D6AC237

About this manual

The PR PR-3001 is a soil tension transmitter designed for agricultural use to monitor soil moisture status. It features a white PVC plastic tube housing, supports wide voltage power supply (10-24V), and utilizes standard Modbus-RTU 485 communication with a range of up to 2000 meters. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Hardware Connection
  • Configuration Software
  • Communication Protocol
  • Common Issues

Specifications

Operating Temperature0℃-60℃
Measurement Range-100kpa-0
Measurement Accuracy±0.5kpa (25℃)
Resolution0.1kpa
Power Supply10-24V DC
Protection RatingIP67
Output SignalRS485 (Modbus)
Response Time200ms

Frequently asked questions

What is the maximum communication distance?

The product supports standard Modbus-RTU485 communication with a maximum range of 2000 meters.

What is the default baud rate?

The factory default baud rate is 4800 bit/s, though it can be set to 2400, 4800, or 9600 bit/s.

What is the default device address?

The default device address is 0x01.