Hantek 6000BC/Hantek 6000BD/Hantek 6000BE Digital Oscilloscope User's Manual

Hantek 6000BC/Hantek 6000BD/Hantek 6000BE digital oscilloscope is a portable oscilloscope with small size, light weight, and no external power supply. It has a wide range of applications, including engineering measurement, on-site construction, research, design, education, and intern training. This digital oscilloscope has a range of basic operations and functions, including system requirements, software installation, driver installation, vertical system, horizontal system, trigger system, input connection, oscilloscope settings, signal measurement, display system, etc.


Hantek 6000BC/Hantek 6000BD/Hantek 6000BE Digital Oscilloscope User's Manual - cover page
Brand
Hantek
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
77
File format
PDF
File size
3.1 MB
Published
23 September, 2022
Updated
28 September, 2023
MD5 checksum
80AE631FB41A01609F2BDFDE2F414BBC

About this manual

This document is the user manual for the Hantek 6000BC, 6000BD, and 6000BE digital oscilloscopes. It provides instructions on system requirements, software installation, and driver setup. The guide details the basic operation of the oscilloscope, including the user interface, menu system, vertical and horizontal systems, and trigger settings. It also explains how to connect inputs and configure the device for various measurements. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • System Requirements
  • Software Installation
  • Driver Installation
  • Basic Operation
  • Vertical System
  • Horizontal System
  • Trigger System
  • Input Connection
  • Application Examples

Specifications

Analog Channels4
Bandwidth250/200/100/70 MHz (-3dB)
Input Impedance1MΩ; 25 pF ± 3pF
Input Sensitivity2mV/div to 10 V/div
Vertical Resolution8 bits
Storage Depth64K/CH, 32K/2CH, 16K/4CH
Input Protection400V (DC+AC Peak)
Real-time Sampling Rate1GS/s
Timebase Range2ns/div to 1000s/div
Trigger SourcesCH1, CH2, CH3, CH4
USB InterfaceUSB 2.0
Dimensions175 x 105 x 30 (mm)

Frequently asked questions

What are the system requirements for running the oscilloscope software?

The minimum requirements are Windows XP/Vista/Win7, a 1.00G processor, 256M byte memory, 500M disk free space, and 800 x 600 screen resolution.

What is the input protection rating for the oscilloscope?

The input protection rating is 400V (DC+AC Peak).

What are the available trigger modes?

The available trigger modes are edge, pulse, video, and alternate.