This document describes the features and characteristics of the YHK and YHK-ECM series low energy consumption cassette fan coil units, including fan absorption, water pressure drop, sound power, heating and cooling emissions, etc.
This document provides technical specifications and performance data for the new YHK chilled water cassette fan coil units. The units feature an innovative design with seven different sizes, high control flexibility, and silent operation using radial fans with wing profile blades. They are available in 2-pipe or 4-pipe configurations and can be equipped with electric resistance heating elements.
| Standard color | RAL 9003 |
|---|---|
| Condensate pump maximum head | 650 mm |
| Insulation class | Class B |
| Fan motor supply | 230V/50Hz single phase |
| Heat exchanger material | Copper tubes with bonded aluminium fins |
The standard colour is RAL 9003, though other colours are available on request.
The integral condensate pump has a maximum head of 650 mm.
Cooling is rated at entering air temperature +27°C dry bulb, +19°C wet bulb, and water temperature +7/12°C.