SONBEST SM2801BD RS485 Soil Moisture Sensor User Manual

This document is the SM2801BD RS485 bus interface display type soil moisture sensor user manual, which introduces the product features, specifications, installation and wiring information.


SONBEST SM2801BD RS485 Soil Moisture Sensor User Manual - cover page
Brand
SONBest
Category
sensor
Document type
User Manual
Language
English
Pages
5
File format
PDF
File size
247 KB
Updated
02 October, 2023
MD5 checksum
2136BDF7A396DAA012CB4228ADE5FB4D

About this manual

This manual provides instructions for the SONBEST SM2801BD, a soil moisture sensor utilizing a high-precision sensing core. It supports the standard RS485 MODBUS-RTU protocol for easy integration with PLCs and DCS systems. The device features an LCD display and can be customized for various output methods including RS232, CAN, 4-20mA, and wireless options like ZigBee and LoRa.

What's inside

  • Technical Parameters
  • Wiring Instructions
  • Communication Protocol
  • Read Data
  • Data Address Table
  • Read and Modify Device Address
  • Read and Modify Baud Rate
  • Read Correction Value
  • Disclaimer
  • Contact Us

Specifications

Moisture measuring range0~24%
Moisture measuring accuracy±3% @25 ℃
Communication InterfaceRS485
Default baud rate9600 8 n 1
Power supplyDC9~24V 1A
DisplayLCD
Running temperature-40~80°C
Working humidity5%RH~90%RH

Frequently asked questions

What is the default device address?

The default device address is 1 when the device is shipped.

What is the default baud rate?

The default baud rate is 9600, 8, n, 1.

What is the moisture measuring accuracy?

The moisture measuring accuracy is ±3% at 25°C.

What power supply is required?

The device requires a DC power supply of 9~24V at 1A.