This operating instructions booklet covers the Panasonic WV-7260 heavy duty outdoor Pan/Tilt Head and the matching WV-7360 Remote Control Unit. The head pans from 10° to 340° at 7.2°/second and tilts up 15° and down 60° at 3.6°/second, and it can be mounted directly on a flat surface with four hex head bolts. The remote control unit, which can be mounted in an optional 19-inch rackmount frame, supplies 24V AC to one Pan/Tilt Head and camera housing and 16V DC to a motorized zoom lens.
The document lists the precautions for both units, the major operating controls and their functions, installation and camera housing mounting, terminal strip and video cable connections, and a wiring table between the WV-7260 and WV-7360. It then describes operation of the pan/tilt, zoom, focus, iris, defroster and wiper controls and explains how to adjust the pan and tilt limit stops, ending with a typical system connection diagram.
| Panning angle | 10° to 340° |
|---|---|
| Panning speed | 7.2°/second |
| Tilting range | Up 15°, down 60° |
| Tilting speed | 3.6°/second |
| Remote Control Unit input power | 120V +10% (108~132V) AC 60Hz |
| Remote Control Unit ambient temperature | 14°F to 122°F (-10°C to +50°C), indoor use, below 90% humidity |
| Pan/Tilt Head ambient temperature | -4°F to 122°F (-20°C to +50°C), outdoor use |
| Mounting holes | 4 holes, 3/8 inch (4-φ9mm) |
| Control cable length | 25-7/16 inch (700 mm) |
| Camera housing mounting bolts | Four M8x20mm (5/16"x13/16") hex head bolts with washers |
| Power cord length | 6 feet (1.8 m) |
| Zoom lens control voltage | TELE +6V DC, WIDE +6V DC, FOCUS NEAR/FAR ±6V DC, IRIS OPEN/CLOSE ±6V DC |
| Number of Pan/Tilt Heads controlled | One per Remote Control Unit |
The camera can be panned from 10° to 340° at 7.2°/second and tilted up 15° and down 60° at 3.6°/second.
The Remote Control Unit can control only one Pan/Tilt Head.
It requires a 60Hz grounded outlet supplying 108V AC to 132V AC, preferably 120V AC.
The installation is described for outdoor camera housings such as the Model WV-7150/7160, with 8 or 9 conductors wired to the WV-7150 and 14 or 15 conductors to the WV-7160.