Futaba GV-1 Governor Instruction Manual

This document provides instructions for using the engine governor for the Futaba GV-1 model helicopter, including setting precautions, operating precautions, assembly and adjustment steps, and function descriptions.


Futaba GV-1 Governor Instruction Manual - cover page
Brand
Futaba
Document type
User Manual
Language
English
Pages
49
File format
PDF
File size
289 KB
Published
09 August, 2012
Updated
28 September, 2023
MD5 checksum
D9ABA7F4A31B50BED634CC1DDD294194

About this manual

The Futaba GV-1 is an engine governor designed for model helicopters that automatically maintains constant rotor RPM by suppressing variations in engine speed due to load changes. It features a magnetic sensing system, an LCD panel for displaying engine speed and set data, and allows fuel mixture control settings.

This instruction manual covers precautions, assembly, adjustment of the magnet and sensor, connection details, and descriptions of various functions including the LCD display and edit keys. It also includes reference specifications, parameter sheets, and repair service information.

What's inside

  • Precautions
  • Set contents
  • Nomenclature
  • Overview of GV-1 operation
  • Mounting the magnet and sensor
  • GV-1 connections
  • LCD display and edit keys
  • Description of functions
  • Specifications
  • Repair service

Specifications

Control systemDigital advanced control
Speed pick-up methodDirect detection of engine rotation by magnetic sensor
Control resolution0.1Hz (+6rpm)
Speed stability accuracy1%
Control response20mS
Speed control range1000~2100rpm (rotor speed)
Display type8 characters dot matrix liquid crystal display
Operating voltage rangeDC 3.8V~6.0V
Current drain40mA (at 4.8V, including sensor)

Frequently asked questions

What is the speed control range of the GV-1?

The governor controls rotor speeds from 1000 to 2100 rpm.

How does the GV-1 detect engine speed?

It uses a magnetic sensing system for direct detection of engine rotation.

What is the operating voltage range for the GV-1?

The device operates within a DC voltage range of 3.8V to 6.0V.