STMicroelectronics AN3110 Application Note: Using the STVM100 to Automatically Adjust VCOM Voltage in E-Paper

This application note briefly describes the basic principle of e-paper so that the user can understand the necessity of an accurate VCOM voltage setting and how the STVM100 can be used for this purpose.


STMicroelectronics AN3110 Application Note: Using the STVM100 to Automatically Adjust VCOM Voltage in E-Paper - cover page
Brand
STMicroelectronics
Document type
Application Note
Language
English
Pages
10
File format
PDF
File size
272 KB
Published
06 August, 2012
Updated
30 September, 2023
MD5 checksum
26F0FBC401144B6CF298FC9BC0C55CB4

About this manual

Electronic paper (e-paper) devices require precise setting of the common electrode voltage (VCOM) to prevent image artifacts like 'ghosting'. This document describes the general principles of electrophoretic display technology and explains why accurate VCOM calibration is necessary for high-quality images.

The note details how the STVM100 digital calibrator can replace traditional mechanical potentiometers. It provides a circuit example using an external resistive voltage divider and operational amplifier, controlled via an I2C interface to adjust VCOM in 128 steps. Additionally, it describes an auto-adjustment demonstration kit that facilitates calibration by reading target values from barcodes or manual input.

What's inside

  • General principle of e-paper
  • E-paper display layout
  • Basic e-paper pixel schematic
  • E-paper VCOM calibration using the STVM100
  • STVM100 auto-adjustment demonstration kit
  • Auto-adjustment demonstration kit test results

Specifications

Typical VCOM distribution range-0.5 V to -2.5 V
Maximum error of auto-adjustment kit11 mV

Frequently asked questions

How does the auto-adjustment kit determine the target VCOM?

It allows the user to input the target value manually or by scanning a barcode on the e-paper PC board.

What is the maximum error achieved by the auto-adjustment kit?

The test results show a maximum difference of 11 mV between the target voltage and the measured voltage.