Lab.gruppen fP 2600 Power Amplifier Technical Data

The document describes the features and characteristics of a power amplifier, including output power, compact design, low weight, and various functional switches.


Lab.gruppen fP 2600 Power Amplifier Technical Data - cover page
Brand
Lab.gruppen
Category
amplifier
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
64 KB
Published
06 August, 2012
Updated
28 September, 2023
Model
fP 2600
MD5 checksum
0B25766B5690C7FBFEA3F293694EF568

About this manual

The Lab.gruppen fP 2600 is a compact, 2U high power amplifier designed for high-quality touring sound systems and demanding permanent installations. It utilizes the latest semiconductor technology combined with the proprietary Intercooler® copper cooling system to enhance performance.

Key features include a regulated switch-mode power supply that handles wide voltage variations (130V-265V AC) efficiently, minimizing heat generation. The unit offers multiple gain settings via a DIP switch and includes sophisticated protection circuitry such as ALS™ short circuit protection, DC protection, VHF protection, thermal protection, and AC protection.

What's inside

  • Key Features
  • New Features
  • Regulated Switch Mode Power Supply
  • Sophisticated Protection Circuitry
  • Specifications
  • Inputs and Outputs
  • Switches
  • Approvals

Specifications

Max output power (8 ohms)430 W @ 1% THD, 840 W @ 0.1% THD
Max output power (4 ohms)840 W @ 1% THD, 1200 W @ 0.1% THD
Operation voltage (230V version)130 V-265 V AC
Operation voltage (115V version)65 V-135 V AC
Weight (Net)8 kg (18 lbs)
Input connectorsNeutrik Combo XLR type, 3 pin and 1/4" jack
Output connectorsNeutrik 4-pole Speakon® connectors

Frequently asked questions

What is the maximum gain setting for the fP 2600?

The maximum amplifier gain can be set to 41 dB.

Does the fP 2600 have short circuit protection?

Yes, it includes ALS™ (Adaptive Limiting System) short circuit protection.

What is the THD at 1 kHz and -1 dB under clip?

The Total Harmonic Distortion is 0.01%.

Download PDF (64 KB)