STMicroelectronics AN2870 L6585DE Combo IC Application Note

The L6585DE is a combo IC for electronic ballasts that offers the designer a high performance PFC stage, high capability half bridge high voltage drivers, a fully programmable control and an enhanced set of protections.


STMicroelectronics AN2870 L6585DE Combo IC Application Note - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Application Note
Language
English
Pages
41
File format
PDF
File size
1.6 MB
Published
06 August, 2012
Updated
30 September, 2023
MD5 checksum
1DBEC7182E7775C89D0571BBF9F742E5

About this manual

The document introduces the L6585DE combo IC, a single-chip solution designed for high-performance electronic ballasts. It combines a transition mode PFC converter with a half-bridge controller and high-voltage drivers to drive fluorescent lamps efficiently while meeting safety and power factor requirements.

The note details the internal architecture of the L6585DE, including its PFC section with THD optimization and over-voltage/over-current protection, and its ballast controller section featuring programmable oscillators, preheating/ignition timing, and end-of-life detection. It also provides guidance on designing the PFC and ballast stages using the device.

What's inside

  • Introduction
  • Typical configuration
  • Lamp requirements
  • L6585DE combo IC
  • Device blocks description
  • PFC section
  • Ballast controller section
  • Designing with L6585DE
  • PCB hints
  • Revision history

Specifications

PFC driver source current300 mA
PFC driver sink current600 mA
Half-bridge driver source current290 mA
Half-bridge driver sink current480 mA
High voltage driver rating600 Vdc
Package typeSO20

Frequently asked questions

What is the main function of the L6585DE?

The L6585DE embeds both a PFC converter and a ballast regulator in a single chip to design complete high power electronic ballasts.

How does the L6585DE detect end-of-life (EOL)?

It uses an internal window comparator that can be configured to detect EOL status based on either lamp-to-ground or block capacitor-to-ground voltage levels.

What is the typical frequency used for fluorescent lamp operation?

A frequency greater than 20 kHz is typically used to reduce the size of the ballast and increase the light efficiency of the lamp.