STMicroelectronics AN2510 L6585D Application Note

This application note introduces the L6585D control IC, a new PFC control IC for electronic ballasts. This IC integrates both PFC and half-bridge sections, and embeds a wide range of features to provide an energy saving and cost effective solution.


STMicroelectronics AN2510 L6585D Application Note - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Application Note
Language
English
Pages
22
File format
PDF
File size
460 KB
Published
06 August, 2012
Updated
30 September, 2023
Model
L6585D
MD5 checksum
87CFA44AF03F8EC452B415BB90AE6F55

About this manual

This document describes the L6585D, a high-voltage single-chip control IC designed to manage electronic ballasts for fluorescent lamps. The device integrates both Power Factor Correction (PFC) and half-bridge sections to provide an energy-saving and cost-effective solution. It features advanced logic for managing lamp critical conditions, including pre-heating, ignition, and fault detection, while optimizing harmonic content mitigation.

What's inside

  • L6585 Integrated circuit
  • Device blocks description
  • Start-up and shutdown
  • PFC section
  • Error amplifier
  • Over-voltage and feedback disconnection detection
  • Zero Current Detection and triggering block
  • Multiplier block
  • Half-bridge current sensing
  • End-of-life detection

Specifications

PFC driver source current300 mA
PFC driver sink current600 mA
Half-bridge driver source current290 mA
Half-bridge driver sink current480 mA
PFC gate driver pulse frequency15 kHz
ZCD starter maximum frequency15 kHz
E/A output low clamp voltage2.25 V
E/A output high clamp voltage4.2 V
CTR internal comparator reference3.4 V
INV voltage threshold for latched stop1.2 V

Frequently asked questions

What is the L6585D designed for?

The L6585D is designed to manage electronic ballasts for fluorescent lamps, including both Power Factor Correction and half-bridge sections.

How does the L6585D handle lamp pre-heating and ignition?

The device allows independent adjustment of pre-heating and ignition durations and includes innovative circuitry for improved lamp voltage control during ignition.

What happens during the start-up phase regarding the PFC section?

During start-up, an internal structure forces the PFC gate driver to switch for the first cycles at a typical frequency of 15 kHz until the ZCD signal is generated.

How does the L6585D detect over-voltage conditions?

It uses a fast OVP detector based on a resistive divider connected to the CTR pin, and stops the PF gate driver if the E/A output goes below 2.25 V.