STMicroelectronics AN2446 Application Note

AN2446 application note, introduces the features and functions of STEVAL-IHT002V1 intelligent thermostat. This thermostat is based on ST7Ultralite MCU, it can drive the compressor, replace PTC and directly drive the start winding. Stall rotor detection is also implemented. Both functions are oriented to reduce the total power consumption. It can be used for small or medium compressors


STMicroelectronics AN2446 Application Note - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Application Note
Language
English
Pages
13
File format
PDF
File size
228 KB
Published
06 August, 2012
Updated
30 September, 2023
MD5 checksum
5E3592DFF9552F4965844640B133CD10

About this manual

This document describes the STEVAL-IHT002V1 evaluation board, a low-cost solution designed to replace mechanical thermostats in compressor-based applications. The board utilizes an 8-pin ST7Ultralite microcontroller to manage the RUN and START windings of the compressor, implement stall rotor detection, and optimize power consumption.

The application note details the circuit description, system operation including temperature regulation and dead-time management, and provides instructions for customizing both the software and hardware modifications to adapt the board to specific compressor requirements.

What's inside

  • STEVAL-IHT002V1 overview
  • Circuit description
  • Cabinet temperature regulation
  • Dead-time
  • Compressor start-up sequence
  • Stall rotor detection
  • Scope waveforms
  • Customization: software and hardware modifications

Specifications

MCU TypeST7Ultralite
Internal Clock1 MHz
Flash Memory1 KByte
Temperature Range-23 °C to +10 °C
Sampling Rate50 times per second
START Winding Duration500ms
Stall Rotor Monitoring Time5 seconds
AC Switch Temperature Limit85 °C
Power On Delay3 seconds

Frequently asked questions

What is the purpose of the STEVAL-IHT002V1 evaluation board?

It is designed to replace existing mechanical thermostats in compressor-based applications.

How does the system detect a stalled rotor?

It monitors the temperature of the AC switch driving the RUN winding; a faster temperature increase indicates a stall.

What is the default duration for the START winding supply?

The START winding is supplied for 500ms before being turned off.

At what temperature is the compressor prevented from turning on?

The compressor is not turned on if the AC switch temperature exceeds 85 °C or drops below 0 °C.