EXTECH EX730 800 Amp AC/DC True RMS Clamp Meter User's Guide


EXTECH EX730 800 Amp AC/DC True RMS Clamp Meter User's Guide - cover page
Brand
EXTECH
Category
Other Electronics
Document type
User Manual
Language
English
Pages
11
File format
PDF
File size
470 KB
Published
01 August, 2012
Updated
29 September, 2023
MD5 checksum
ECEE216E53CCF6545864165E1A3B7C1D

About this manual

The EXTECH EX730 is a clamp meter designed to measure AC and DC current up to 800A, as well as voltage, resistance, capacitance, frequency, temperature, and continuity. The device features a backlit LCD display, data hold, peak capture, and automatic power-off functions to ensure safe and accurate measurements.

What's inside

  • Introduction
  • Safety Notes
  • Description
  • AC/DC Current Measurements
  • AC/DC Voltage Measurements
  • Resistance Measurements
  • Capacitance Measurements
  • Frequency Measurements
  • Temperature Measurements
  • Continuity and Diode Test

Specifications

AC Current Range40.00A, 400.0A, 800A
DC Current Range40.00A, 400.0A, 800A
AC Voltage Range400.0mV to 600V
DC Voltage Range400.0mV to 600V
Resistance Range400.0Ω to 40.00MΩ
Capacitance Range4.000nF to 4.000mF
Frequency Range4.000kHz
Temperature Range-4 to 1400 °F / -20 to 760 °C

Frequently asked questions

What is the maximum current measurement range?

The maximum current measurement range is 800A AC/DC.

Can the meter measure both AC and DC voltage?

Yes, the meter can measure both AC and DC voltage up to 600V.

How do I zero the DC current measurement?

Press the DC ZERO button to zero the meter display.

What happens if I leave the meter unused for a long time?

The meter will automatically turn off after approximately 25 minutes to conserve battery life.

Download PDF (470 KB)

More EXTECH Manuals


View all EXTECH manuals →