This manual provides safety installation instructions for Pentair PG2000® Electric Pump.
This manual provides step-by-step instructions for installing the Pentair PG2000 fiber optic lighting system. It covers critical safety precautions regarding electrical shock and proper placement distances from pools. The guide details the preparation of conduits, installation of lens housings, and the specific procedure for feeding or pulling AmerGlow cables.
| Power Consumption | Approximately 200 Watts |
|---|---|
| Dimensions | 15 in. x 10% in. x 12 in. |
| Weight | 20 Ibs |
| Maximum Fiber Capacity | 600 FIBERworks fibers |
The PG2000 must be installed by a licensed or certified electrician in accordance with the National Electrical Code.
The unit should be located at least 5 feet from the pool, or the minimum distance required by local codes.
You must use prescribed FIBERworks FiberKnife and shield; do not use mechanical cutters or torch-heated blades.