About this manual

This document provides installation guidelines for the Pentair Large Stainless Steel Niche, specifically designed for concrete and gunite pool applications. It covers safety warnings regarding electrical shock, required bonding and grounding procedures, and specific orientation requirements to ensure proper operation of compatible underwater light fixtures.

The guide is divided into sections for USA and Canada installations, detailing differences in electrical code compliance (NEC vs CE), junction box placement distances, and conduit specifications. Key steps include locating the niche on a vertical wall at least 18 inches below the water surface, orienting the pilot screw hole to the 12 o'clock position, and securely bonding the fixture housing to all metallic items within five feet of the pool.

What's inside

  • General Information for USA Installations
  • Concrete/Gunite Installation Instructions (USA)
  • General Information for Canada Installations
  • Junction/Deck Box Location for Canada
  • Concrete/Gunite Installation Instructions (Canada)

Specifications

Compatible FixturesAmerlite, AmerQuartz, SAm, IntelliBrite, SunGlow II, and SunBrite II
USA Ground Wire SizeNo. 8 AWG
Canada Ground Wire SizeNO. 6 AWG
USA Minimum Depth18 inches below water surface
Canada Maximum Depth600 mm below water surface
Junction Box Distance (Canada)3 m or more from edge

Frequently asked questions

Which light fixtures are compatible with this niche?

This niche is designed for use only with Pentair Water Pool and Spa wet niche light fixtures, specifically Amerlite, AmerQuartz, SAm, IntelliBrite, SunGlow II, and SunBrite II.

What is the required orientation for installing the niche?

The niche must be oriented so that the pilot screw hole is at the 12 o'clock position to ensure proper bonding.

What size ground wire is required for USA installations?

USA installations require a No. 8 AWG ground connector located at the rear of the niche.

What size ground wire is required for Canada installations?

Canada installations require a No. 6 AWG ground connector located at the rear of the niche.