This manual describes how to install Pentair Plaster Ring, including requirements before installation, installation method, and precautions, etc.
This document provides safety warnings and general information regarding the installation of Pentair plaster rings. It emphasizes compliance with the National Electrical Code, proper grounding, and bonding requirements to prevent electrical shock hazards during pool construction.
The guide details specific steps for installing the plaster ring in concrete or gunite pools, including positioning over existing niches, securing the unit, connecting bonding wires, and ensuring a flush finish around the niche opening.
The top edge of the underwater light's lens must be at least 18 inches below the surface of the water in the pool.
The niche or plaster ring must be electrically bonded and grounded via a No. 8 AWG ground connector located at the rear of the niche.
The junction box must be located at least 48 inches from the edge of the pool.