Pentair SPABRITE & AQUALIGHT Light Niche Installation Guide

This is an installation instruction document that introduces the installation method of SPABRITE® & AQUALIGHT® LIGHT NICHE products.


Pentair SPABRITE & AQUALIGHT Light Niche Installation Guide - cover page
Brand
Pentair
Category
Other
Document type
Installation Guide
Language
English
Pages
8
File format
PDF
File size
444 KB
Published
12 July, 2012
Updated
30 September, 2023
MD5 checksum
9D2C8A5F03DDA5FED92A3B3C3DEB7EA9

About this manual

This manual provides installation procedures for Pentair SPABRITE and AQUALIGHT light niches in swimming pools and spas. It covers critical safety warnings regarding electrical shock and mandates installation by a licensed electrician in accordance with the National Electrical Code (NEC). The guide details specific requirements for electrical systems, including the use of Ground Fault Circuit Interrupters (GFCI) and proper bonding of metallic items within five feet of the pool.

What's inside

  • General Information
  • Vinyl Liner/Fiberglass Pool Installation
  • Concrete/Gunite Pool Installation
  • Electrical Safety Requirements
  • Bonding and Grounding
  • Replacement Parts
  • Technical Data

Specifications

Bonding Wire SizeNo. 8 AWG
Junction Box Height Above Water8 inches minimum
Junction Box Height Above Ground4 inches minimum
Distance from Pool Wall48 inches minimum
Lens Depth Below Surface18 inches minimum

Frequently asked questions

Who must install this niche fixture?

This niche - fixture housing must be installed by a licensed or certified electrician.

What is the minimum depth for the light lens below the water surface?

The top edge of the underwater light's lens must be at least 18 inches below the surface of the water.

What wire size is required for bonding?

A No. 8 AWG bond wire must be used to bond the niche-fixture housing to other metallic items.