This document is the user manual for the APRILAIRE® Energy Recovery Ventilator model 8100, including safety, operating, and maintenance instructions. The product is covered by a five-year warranty, guaranteeing the quality of materials and workmanship. Within the warranty period, defective parts can be replaced free of charge.
The Aprilaire Model 8100 Energy Recovery Ventilator is designed to remove indoor air pollution and provide a constant supply of fresh air to the home. It utilizes a special EnergyMax transfer core to pre-heat or pre-cool incoming fresh air using the indoor conditioned air, reducing energy requirements for heating and cooling systems. The unit is designed for continuous operation to provide a comfortable and healthy environment year-round.
This document serves as the owner's manual, including safety warnings, operating instructions, and maintenance guidelines. It details the specific maintenance schedule, such as cleaning aluminum filters every six months and inspecting the blower compartments. The manual also outlines the limited warranty terms provided by Research Products Corporation.
| Voltage | 120 VAC |
|---|---|
| Warranty Period | five (5) years |
| Filter Cleaning Interval | every six months |
| Transfer Core Cleaning Interval | annually |
The Energy Recovery Ventilator is expressly warranted for five (5) years from the date of installation.
The aluminum filters should be cleaned every six months and recoated with Super Filter Coat.
The EnergyMax transfer core should be slid out annually to be vacuumed.