Agilent 6890N Network Gas Chromatography System Product Leaflet

Agilent 6890N 2 Gas Chromatography System is a highly efficient and fast gas chromatograph with the characteristics of fast installation and configuration, rapid method establishment, simplified sample preparation, results in minutes, increased productivity, reliable compliance with regulations and lasting reliability.


Agilent 6890N Network Gas Chromatography System Product Leaflet - cover page
Brand
Agilent
Document type
Product Leaflet
Language
Spanish
Pages
16
File format
PDF
File size
8.6 MB
Published
09 July, 2012
Updated
30 September, 2023
Model
6890N
MD5 checksum
43C8CAE0DAD16C60019FE85CC512184E

About this manual

This document introduces the Agilent 6890N Network Gas Chromatography System, emphasizing its ability to provide new pathways for gas chromatography through automation and networking. Key benefits include rapid installation and configuration, simplified method setup, streamlined sample preparation, and fast result generation within minutes.

The system features advanced electronic pneumatic control (EPC) of the fourth generation for excellent reproducibility and a modular design that allows easy updates to meet evolving needs. It supports a wide range of detectors, including Mass Selective Detectors (MSD), Flame Ionization Detectors (FID), Thermal Conductivity Detectors (TCD), and others, integrated with Agilent ChemStation Plus software for data management. This manual is written in Spanish.

What's inside

  • Introduccion de muestra
  • Detectores
  • Control del instrumento y tratamiento de datos
  • Control electronico de la neumatica
  • Congelacion del tiempo de retencion
  • Modularidad
  • Preparacion simplificada de muestra
  • Sin preparacion de muestra
  • Derivatizacion reducida
  • GC mas rapida

Specifications

System TypeNetwork Gas Chromatography System
Software FamilyAgilent ChemStation Plus

Frequently asked questions

How does the Electronic Pneumatic Control (EPC) improve performance?

The fourth-generation EPC maintains constant pressures and flows, providing excellent reproducibility of retention time.

What is the maximum volume that can be injected in a single injection using the Agilent 6890N system?

The system allows injections of up to 50 pl in a single injection when using the cold on-column or programmable temperature vaporization injector.

How many times faster can real-time gas chromatography be compared to standard GC using the Agilent 6890N system?

The system provides real-time gas chromatography that is two, five, or even ten times faster than standard GC.

What is the typical retention time for Dichlorvos when analyzed using the MSD detector with splitless injection?

The retention time for Dichlorvos is 5.862 minutes when analyzed using the MSD detector with splitless injection.

Download PDF (8.6 MB)

More Agilent Manuals


View all Agilent manuals →