Agilent Technologies Brilliant II SYBR Green QRT-PCR Master Mix with ROX 1-Step INSTRUCTION MANUAL

This manual provides instructions for using Brilliant II SYBR® Green QRT-PCR Master Mix.


Agilent Technologies Brilliant II SYBR Green QRT-PCR Master Mix with ROX 1-Step INSTRUCTION MANUAL - cover page
Brand
Agilent
Document type
User Manual
Language
English
Pages
22
File format
PDF
File size
249 KB
Published
06 June, 2012
Updated
01 October, 2023
MD5 checksum
B3372B25676371ED4FA80947BDE42028

About this manual

This document provides instructions for the use of the Agilent Brilliant II SYBR Green QRT-PCR Master Mix with ROX, 1-Step kit. The kit is designed for quantitative reverse transcription PCR (QRT-PCR) to analyze gene expression in a single tube and buffer. It includes two formulations: a High ROX master mix (500 nM final concentration) compatible with ABI PRISM systems, and a Low ROX master mix (30 nM final concentration) compatible with Stratagene Mx and ABI 7500 systems.

What's inside

  • Materials Provided
  • Storage Conditions
  • Additional Materials Required
  • Introduction
  • Features of Kit Components
  • Preprotocol Considerations
  • RNA Isolation
  • Preparing the Reactions
  • RT-PCR Cycling Program
  • Troubleshooting

Specifications

Final ROX concentration (High)500 nM
Final ROX concentration (Low)30 nM
Recommended amplicon sizeup to 300 bp

Frequently asked questions

How should the master mix be stored after thawing?

Store at 4°C. Once thawed, full activity is guaranteed for 6 months.

What is the maximum recommended length for amplicons when using this kit?

The kit is ideal for amplifying targets that are up to 300 base pairs long.

What is the final concentration of ROX reference dye in reactions using the high ROX master mix?

Reactions prepared with the high ROX master mix contain a final concentration of 500 nM.

How long is full activity guaranteed for the master mix after it has been thawed?

Once thawed, full activity is guaranteed for a period of six months.