Analog Devices ADM2482E/ADM2487E Isolated RS-485 Transceiver Datasheet

The document introduces ADM2482E/ADM2487E, a 2.5 kV isolated RS-485 transceiver with an integrated transformer driver. It features an integrated oscillator driver, ±15 kV ESD protection on RS-485 input/output pins, compliance with TIA/EIA-485-A-98 and ISO 8482:1987(E) standards, etc.


Analog Devices ADM2482E/ADM2487E Isolated RS-485 Transceiver Datasheet - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
20
File format
PDF
File size
665 KB
Published
07 May, 2012
Updated
29 September, 2023
MD5 checksum
6D239C6E05989738F356119B253EC088

About this manual

The ADM2482E and ADM2487E are isolated data transceivers that provide +15 kV ESD protection and support high‑speed half‑duplex or full‑duplex communication on multipoint RS‑485/RS‑422 networks. They integrate an oscillator driver, a three‑state differential line driver, and a differential input receiver in a single iCoupler™ package, and are available in a 16‑lead wide‑body SOIC.

These devices are intended for industrial field networks, isolated RS‑485/RS‑422 interfaces, and other multipoint data transmission systems. They meet TIA/EIA‑485‑A‑98, ISO 8482:1987, UL 1577, and VDE certifications, and operate over a temperature range of –40 °C to +85 °C.

What's inside

  • Features
  • Applications
  • General Description
  • Functional Block Diagram
  • Specifications
  • Timing Specifications
  • Package Characteristics
  • Regulatory Information
  • Insulation and Safety Specifications
  • Pin Configuration

Specifications

Data Rate500 kbps (ADM2487E) / 16 Mbps (ADM2482E)
Supply Voltage5 V or 3.3 V operation
Isolation Voltage2500 Vrms for 1 minute
Operating Temperature Range–40 °C to +85 °C
Short‑Circuit Output Current250 mA

Frequently asked questions

What is the maximum data rate for the ADM2482E and ADM2487E?

The ADM2482E supports up to 16 Mbps, while the ADM2487E supports up to 500 kbps.

What isolation voltage rating do these transceivers meet?

They are rated for 2500 Vrms isolation for a 1‑minute test.

What supply voltages can be used with the devices?

Both 5 V and 3.3 V supplies are supported on the logic side.

What are the temperature limits for operation?

The devices operate from –40 °C up to +85 °C.