Analog Devices ADM691A/ADM693A/ADM800L/M Datasheet

This document is the user manual for ADM691A/ADM693A/ADM800L/M products published by Analog Devices. The product is a microprocessor supervisory circuit with low power consumption, precise voltage monitoring, automatic battery backup power switching and other features.


Analog Devices ADM691A/ADM693A/ADM800L/M Datasheet - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
12
File format
PDF
File size
339 KB
Published
03 May, 2012
Updated
30 September, 2023
Model
ADM800
MD5 checksum
EF0A4D49141D715E1A6E72B357ACC73E

About this manual

The ADM691A, ADM693A, ADM800L, and ADM800M are microprocessor supervisory circuits that offer power‑on reset, battery backup switching, watchdog timer, and power‑fail detection. They are supplied in 16‑pin DIP, SO, and for ADM691A also a space‑saving TSSOP package.

The document lists electrical specifications such as operating voltage range, supply current, reset thresholds, and watchdog timing, and includes pin‑out tables, typical performance curves, and ordering information.

What's inside

  • General Description
  • Specifications
  • Pin Descriptions
  • Typical Performance Curves
  • Watchdog and Reset Timing
  • Product Selection Table
  • Ordering Guide

Specifications

Operating Voltage Range0 – 5.5 V
Supply Current (Excludes I_OUT)70 – 100 µA
Reset Voltage Threshold (ADM691A/ADM800L)4.5 – 4.75 V
Watchdog Timeout Period (Internal Oscillator)1.0 – 2.25 s
Available Packages16‑pin DIP, SO, TSSOP (ADM691A)

Frequently asked questions

What is the reset voltage threshold for the ADM691A?

The reset voltage threshold for the ADM691A ranges from 4.5 V to 4.75 V.

What is the typical supply current of these devices?

The supply current (excluding I_OUT) is specified as 70 µA to 100 µA.

In which packages are the devices offered?

All parts are offered in 16‑pin DIP and SO packages, and the ADM691A is also available in a TSSOP package.

What is the voltage range for battery‑backup switching?

Battery‑backup switching operates over a voltage range of 0 V to 5.5 V.