Linear Technology LTC1062 5th Order Lowpass Filter Handbook

LTC1062 1062fd 10Hz 5th Order Butterworth Lowpass Filter is a lowpass filter with no DC error, low passband noise, operates DC to 20kHz, operates on a single 5V supply or up to ±8V, 5th order filter, maximally flat response, internal or external clock, cascadable for faster rolloff, buffer available.


Linear Technology LTC1062 5th Order Lowpass Filter Handbook - cover page
Brand
Linear Technology
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
16
File format
PDF
File size
191 KB
Published
11 April, 2012
Updated
01 October, 2023
MD5 checksum
A2622EC8EC29AECB95ECAABBD3013917

About this manual

The LTC1062 is a 5th‑order all‑pole maximally flat low‑pass filter with no DC error. Its architecture removes DC offset and low‑frequency noise by placing the filter outside the DC path, and it can operate from a single 5 V supply up to +8 V. The filter’s cutoff frequency is set by an internal clock that can be externally driven, and two devices can be cascaded for a 10th‑order response.

The document lists absolute maximum ratings, electrical characteristics, typical performance curves, and package details. It includes application notes such as antialiasing, digital voltmeter scaling, and filtering of AC signals riding on high DC voltages, along with guidance on oscillator frequency adjustment and external clock usage.

What's inside

  • Features
  • Applications
  • Description
  • Absolute Maximum Ratings
  • Electrical Characteristics
  • Typical Performance Characteristics
  • Block Diagram
  • Applications Information
  • Package Description
  • Related Parts

Specifications

Supply Voltage Range+2.5 V to +9 V
Input Frequency Range0 Hz to 20 kHz
Clock‑to‑Cutoff Ratio100:1
Maximum Attenuation (100 kHz clock, 1 kHz cutoff)≈ 64 dB
RMS Noise (DC‑17 kHz)100 µV

Frequently asked questions

What is the typical RMS noise of the LTC1062?

The RMS noise from DC to 17 kHz is about 100 µV.

How many LTC1062 devices can be cascaded?

Two LTC1062 devices can be cascaded to form a 10th‑order filter.

How can the oscillator frequency be adjusted?

Insert a 50 kΩ potentiometer in series with Cosc or use an external capacitor to change the oscillator frequency.

Download PDF (191 KB)