This manual explains how to start and control the AD-122B dehumidifier, including setting the desired humidity level and monitoring operation status. It also describes the control panel functions and automatic shut‑off behavior.
Additional sections cover proper drainage setup, safety precautions during use, and regular cleaning and maintenance procedures to keep the unit operating efficiently. This manual is written in Japanese.
| Input Voltage | 110V 60Hz |
|---|---|
| Dimensions (W×D×H) | 520×310×210 mm |
Press the power button and set the desired humidity level on the control panel; the unit will start automatically when the indoor humidity exceeds the set value.
Connect a PVC drain hose (15 mm) to the drain outlet, place it at a lower level, and ensure the hose is horizontal to allow water to flow out.
Do not use an extension cord, avoid operating the unit on uneven surfaces, and keep the intake and exhaust openings clear of obstructions.