This user manual explains how to set up, operate, and maintain the AD-1641FB dehumidifier. It includes step‑by‑step instructions for turning the unit on, adjusting timer settings, and draining water, as well as safety precautions to prevent accidents.
The guide also covers routine maintenance such as cleaning the air‑filter, emptying and reinstalling the water tank, and troubleshooting common issues. Technical specifications like voltage, power consumption, refrigerant type, and dimensions are listed for reference. This manual is written in Chinese.
| Voltage / Frequency | 110 V / 60 Hz |
|---|---|
| Power Consumption | 24 W |
| Rated Current | 2.2 A |
| Refrigerant Type | HFC‑134a |
| Refrigerant Charge | 1359 g |
| Water Tank Capacity | 4 L (auto‑stop at 3.3 L) |
| Weight | 8.5 kg |
| Dimensions (H × W × D) | 505 mm × 160 mm × 330 mm |
It operates on 110 V at 60 Hz.
The tank holds 4 L of water and the unit stops automatically when the level reaches about 3.3 L.
The filter should be cleaned roughly every two weeks.
The dehumidifier consumes about 24 W of power.