This guide provides basic steps for the first power-on and initial setup of a server, as well as detailed installation information for the Sun Blade X6270 Server Module and optional components. It also includes safety and compliance information.
This guide describes the basic steps to power on and boot the Sun Blade X6270 server module. It covers inserting the module into a powered chassis, verifying standby power, applying main power, and powering off the module.
It also explains connecting to ILOM through a serial connection, configuring an IP address with the CLI, registering the system, setting up the platform operating system, drivers, and firmware, upgrading firmware and drivers, and listing related documentation. This manual is written in Chinese.
| Normal/Power LED while SP boots | Slowly blinks: 0.5 s on, 0.5 s off |
|---|---|
| Standby LED blink | 0.1 s on, 2.9 s off |
| Serial console data format | 8N1 |
| Serial console baud rate | 9600 baud default; up to 57600 |
| Serial hardware flow control | Disabled (CTS/RTS) |
| Default ILOM login | Username root, password changeme |
The default username is root and the default password is changeme.
The Normal/Power LED is solid green.
Hold the power button for four seconds.
No, hardware flow control (CTS/RTS) is disabled.