ifm PG27xx704553 Electronic Manometer Operating Instructions

This is an operating manual for electronic pressure gauge PG27xx


ifm PG27xx704553 Electronic Manometer Operating Instructions - cover page
Brand
ifm
Document type
User Manual
Language
English
Pages
27
File format
PDF
File size
431 KB
Published
04 January, 2012
Updated
01 October, 2023
MD5 checksum
A74FA1015275A4F7D7E9D59A18468995

About this manual

This manual provides comprehensive guidance for the ifm PG27xx704553 electronic manometer. It includes safety instructions, installation steps, electrical connection details, and a description of the operating and display elements.

The document also explains the menu structure, parameter configuration, service functions, and technical specifications such as voltage range, current consumption, output types, accuracy, and environmental limits.

What's inside

  • Preliminary note
  • Safety instructions
  • Functions and features
  • Installation
  • Electrical connection
  • Operating and display elements
  • Menu
  • Parameter setting
  • Technical data
  • Factory setting

Specifications

Operating voltage18‑32 V DC
Current consumption< 70 mA (24 V)
Switching frequency50 Hz
Analogue output4‑20 mA / 20‑4 mA
Ambient temperature range-25 °C to 80 °C

Frequently asked questions

What is the recommended tightening torque when installing the sensor?

The recommended tightening torque is 35 Nm.

How many output signals does the unit provide and what are they?

The unit provides two output signals: OUT1 is a binary switching output and OUT2 is an analogue output for system pressure.