The KG (M18) capacitive sensor is a sensor for detecting metal objects. It features a detection range of up to 8 mm, a short response time of just 1 ms, high resistance to interference, easy installation without the need for special tools, and is suitable for a variety of industrial applications.
This document is the operating instructions for the ifm KG (M18) capacitive sensor used to monitor liquid levels and bulk materials. It describes installation, electrical connection, operating and display elements, setting procedures, IO-Link communication, operation and maintenance.
The sensor can be adjusted with its programming button, including basic empty adjustment, full adjustment, improved basic empty adjustment and lock/unlock functions. It also explains LED indications and disposal guidance. This manual is written in Chinese.
| Output type | PNP output (type ...FPKG...) or automatic NPN/PNP detection (type ...FAKG...) |
|---|---|
| Basic empty adjustment liquid level | Container empty until liquid level is at least 20 mm below the sensor |
| Button press duration for basic empty adjustment | 2 to 6 seconds |
| LED indication | Yellow LED off means switching output disabled; yellow LED on means switching output enabled |
Empty the container until the liquid level is at least 20 mm below the sensor, then press and hold the appropriate button for 2 to 6 seconds depending on the selected output state.
The yellow LED being off means the switching output is disabled, and being on means the switching output is enabled.
Yes, the device can be locked electrically to avoid accidental setting changes.
The device operates without maintenance, but the sensing face and surrounding space should be kept free of deposits or foreign matter.